AHU-07, roof plant
Demo data. Fictional facility. Nothing here is live.Supply air temperature · last 24 hours
Supply air temperature, latest reading
62.0 degrees Fahrenheit
Over the 58 °F limit
as of 20:20
Limit 58 °F · Facility policy (demo)
Events in this period: WO-1349 opened 6:23 · WO-1353 opened 9:23 · WO-1356 opened 13:23 · WO-1357 opened 13:23 · WO-1358 opened 14:23.
In OR 1 · a room AHU-07 serves
OR 1 pressure differential
0.02 inches of water
Within the 0 inH2O limit
Normal 0.01 to 0.03 inH2O · as of 20:20
OR 1 humidity
49.4 percent relative humidity
10.6 percentage points under the 60% RH limit
as of 20:20
OR 1 temperature
70.5 degrees Fahrenheit
Within the 75 °F limit
Normal 68 to 73 °F · as of 20:20
In OR 2 · a room AHU-07 serves
OR 2 pressure differential
0.02 inches of water
Within the 0 inH2O limit
Normal 0.01 to 0.03 inH2O · as of 20:20
OR 2 humidity
48.7 percent relative humidity
11.3 percentage points under the 60% RH limit
as of 20:20
OR 2 temperature
70.5 degrees Fahrenheit
Within the 75 °F limit
Normal 68 to 73 °F · as of 20:20
In OR 3 · a room AHU-07 serves
OR 3 pressure differential
0.02 inches of water
Within the 0 inH2O limit
Normal 0.01 to 0.03 inH2O · as of 20:20
OR 3 humidity
49.1 percent relative humidity
10.9 percentage points under the 60% RH limit
as of 20:20
OR 3 temperature
70.5 degrees Fahrenheit
Normal 68 to 73 °F · as of 20:20
On AHU-07 · the unit's own sensors
Cooling coil valve
Responding
as of 20:15
Supply fan
Running
as of 20:15
Filter pressure drop
1.01 inches of water
Over the 1 inH2O limit
Normal 0.3 to 1 inH2O · as of 20:15
Return air humidity
43.9 percent relative humidity
16.1 percentage points under the 60% RH limit
as of 20:20
Supply air temperature
62.0 degrees Fahrenheit
Over the 58 °F limit
Normal 53.5 to 56.5 °F · as of 20:20
Duct static pressure
1.51 inches of water
Within the 1 inH2O limit
Normal 1.2 to 1.8 inH2O · as of 20:20
Repair history
- WO-1358AHU-07: supply air temperature drifting, repair needs approvalToday
- WO-1356AHU-07: supply air temperature drifting, repair needs approvalToday
- WO-1357AHU-07: supply air temperature drifting, repair needs approvalToday
- WO-1353AHU-07: supply air temperature drifting, repair needs approvalToday
- WO-1349AHU-07: supply air temperature drifting, repair needs approvalToday
- WO-1343AHU-07: supply air temperature drifting, repair needs approvalYesterday
- WO-1341AHU-07: supply air temperature drifting, repair needs approval2 days ago
- WO-1334AHU-07: supply air temperature drifting, repair needs approval2 days ago
- WO-1332AHU-07: supply fan belt slipping2 days ago
- WO-1320AHU-07: supply fan noisy6 days ago
- WO-1283AHU-07: filter change3 weeks ago
- WO-1278AHU-07: belt check3 weeks ago
- WO-1273AHU-07: filter pressure over limit3 weeks ago
- WO-1240AHU-07, high humidity in OR 34 weeks ago
- WO-1231Damper not responding4 weeks ago
- WO-1207High humidity alarm, OR 35 weeks ago
- WO-1182Actuator sticking, reset by tech6 weeks ago
- WO-1111AHU-07: belt check (PM)8 weeks ago
- WO-1096Quarterly filter change3 months ago
- WO-1026AHU-07: filter change (PM)3 months ago
- WO-1019AHU-07: belt check (PM)3 months ago
- WO-995AHU-07: belt check (PM)4 months ago
- WO-0988Belt replaced5 months ago
Rooms served, next 24 hours
OR 1
Not in use now
- No case blocks in the next 24 hours
OR 2
Not in use now
- No case blocks in the next 24 hours
OR 3
Not in use now
- No case blocks in the next 24 hours
Room blocks come from the OR schedule. Mono reads times only, never patient details.
Parts on this asset
| Part | On hand | Mono's action | Open |
|---|---|---|---|
| A42 controls actuator Reorder at 2 · used 7 in 90 days | 3 | Reorder in about 2 weeks | |
| B-52 belt kit Reorder at 4 · used 7 in 90 days | 8 | Stocked | |
| FM-3 fan motor Reorder at 2 · used 1 in 90 days | 2 | Needs you · $1,240 | |
| MERV 14 filters Reorder at 12 · used 31 in 90 days | 11 | Ordered 12, arrive Nov 4 | |
| UV-C lamp, OR 3 Reorder at 2 · used 3 in 90 days | 3 | Stocked |